Welcome to the SCI Materials Hub !
Home > XRD > XRD Accessories > Solid / Liquid Sample Trays & Quartz Cell Accessories

Solid / Liquid Sample Trays & Quartz Cell Accessories

  • Product Code:
  • Description:Solid / Liquid Sample Trays & Quartz Cell Accessories
  • Brand:
  • Lead time:Ask for quote
  • Views:
  • Telephone:+86 153-5789-9751; +86 156-0553-2352
  • Keywords:Solid / Liquid Sample Trays & Quartz Cell Accessories, SCI Materials Hub
Solid & Liquid Sample Trays and Quartz Cell Accessories | Product Details
SOLID & LIQUID SAMPLE ACCESSORIES

Solid & Liquid Sample Trays and Quartz Cell Accessories

Sample support, covering and reference components for solid and liquid optical measurement systems. The range includes rimmed-cell lids, quartz-cell lids, solid sample trays, solid sample tray-and-lid sets, solid reference components and liquid sample trays.

Solid Sample Measurements Liquid Sample Measurements Sample Trays Quartz Cell Accessories Reference Components
PRODUCT OVERVIEW

Product Overview

This range provides sample support and covering components for optical measurements of solids, powders, granules and liquids. Different trays and lids secure samples, protect the measurement area, reduce contamination and help maintain consistent sample positioning.

Accessories are available individually, or as a solid sample tray and lid set. The solid reference is a separate reference component. The supplied product information explicitly states that it is not barium sulfate.

Before Ordering
Confirm the instrument model, sample compartment structure, original cell or tray dimensions, solid or liquid application, lid design and reference requirements. Dimensions are not provided in the current specifications; compatibility cannot be determined from product names alone.
ACCESSORY TYPES

Accessory Types

Rimmed-Cell Lid An individual replacement lid for the corresponding rimmed cell design.
Quartz-Cell Lid Fits the corresponding quartz cell to protect the sample and internal measurement area.
Solid Sample Tray Supports powders, granules, thin pieces and other solid samples.
Solid Sample Tray & Lid Set Includes a solid sample measurement tray and lid for complete replacement or matched use.
Solid Reference Component For reference correction in the corresponding solid measurement system. This product is not barium sulfate.
Liquid Sample Tray Holds liquid samples. Confirm capacity, sealing requirements and instrument compatibility before ordering.
PRODUCT RANGE

Product Range

Type / SpecificationSupply FormatMain Use
Rimmed-Cell Lid — 1 PieceSingle PieceReplacement lid for a rimmed cell
Quartz-Cell Lid — 1 PieceSingle PieceReplacement lid for a quartz cell
Solid Sample Tray — 1 PieceSingle PieceSolid sample support
Solid Sample Measurement Tray + Lid — 1 SetOne SetComplete solid measurement assembly
Solid Reference Component — 1 Piece
Not Barium Sulfate
Single PieceSolid measurement reference correction
Liquid Sample Tray — 1 PieceSingle PieceLiquid sample support
KEY FEATURES

Product Features

Solid & Liquid ApplicationsSample support components for both solid and liquid measurements.
Individual Replacement OptionsSelect individual lids, trays and reference components as required.
Matched Set AvailableA solid sample tray-and-lid set helps avoid missing matching components.
Organized Sample PreparationTrays help standardize sample position, loading thickness and measurement area.
Measurement Area ProtectionLids help reduce the effects of dust, sample dispersal and external contact.
Clearly Identified ReferenceThe solid reference is not barium sulfate. Confirm suitability for your measurement method before ordering.
APPLICATIONS

Applications

Solid Reflectance MeasurementsSupport for powders, granules, thin pieces and bulk solid samples.
Liquid Optical MeasurementsLiquid trays for corresponding instrument sample measurements.
Reference CorrectionSolid reference components for baseline or reference procedures before measurement.
Accessory ReplacementReplace original lids or trays individually when damaged or contaminated.
Reduced Sample DispersalLids provide auxiliary covering for powder or granular samples.
Instrument AccessoriesFor compatible spectroscopy, reflectance, color and materials measurement systems.
HOW TO USE

How to Use

01

Check Compatibility

Verify that the instrument, cell, tray and lid designs match.
02

Clean & Inspect

Confirm that components are clean and free of cracks, deformation or visible residue.
03

Load the Sample

Add solid or liquid samples according to the measurement method and maintain consistent preparation.
04

Mount & Measure

Fit the lid or secure the assembly, then measure after confirming stable positioning.
SELECTION GUIDE

Selection Guide

RequirementSuggested OptionKey Checks
Replace a rimmed-cell lid onlyRimmed-cell lidRim design and diameter
Replace a quartz-cell lid onlyQuartz-cell lidCell dimensions and mating arrangement
Matching lid already availableIndividual solid sample trayTray format and depth
Complete solid measurement assemblySolid sample tray + lidInstrument sample compartment design
Reference correction requiredSolid reference componentMeasurement method and reference material
Liquid sample measurementsLiquid sample trayCapacity, sealing and compatibility
CLEANING & CARE

Cleaning & Maintenance

Clean PromptlyRemove remaining sample after measurement to prevent powder or liquid residue from drying.
Separate Components by UseManage solid, liquid and reference components separately to reduce cross-contamination.
Handle GentlyAvoid scratching with hard objects, impacts, drops and excessive clamping.
Compatible CleaningSelect cleaning agents compatible with both the sample and component material.
Protect the ReferenceKeep reference components free from contamination, moisture and direct contact with unknown samples.
Dry StorageDry thoroughly, store separately in closed packaging and label the component name and intended use.
FAQ

Frequently Asked Questions

Are the lids and trays interchangeable?

Compatibility cannot be determined from the names alone. Check the original component's format, diameter, height, locking or rim design and instrument model.

Is the solid reference barium sulfate?

No. The supplied product information explicitly states that it is not barium sulfate. Confirm the actual reference material and applicable measurement methods before ordering.

Does the individual solid sample tray include a lid?

“Solid Sample Tray — 1 Piece” does not indicate that a lid is included. If both are required, select “Solid Sample Measurement Tray + Lid — 1 Set.”

Why are no dimensions listed?

The current specifications do not provide dimensions. Confirm them using the original accessory or instrument model before ordering to avoid an incorrect fit.

Solid & Liquid Sample Accessories ' Specifications & USD Prices
SPECIFICATION · PRICE · PURCHASE

Solid & Liquid Sample Trays and Quartz Cell Accessories

Expand Quick Selection to view all accessories and USD prices. Click any product to smoothly locate and highlight its corresponding row in the price table.

QUICK SELECTION

Quick Selection

Expand list · View prices · Click to locate
Prices are in USD. Dimensions are not provided in the current specifications. Confirm compatibility using the instrument model or original accessory before ordering.
SPECIFICATION & PRICE

Specifications & Prices

All 6 products and corresponding prices
Type / SpecificationDimensionsFinal Price (USD)
Rimmed-Cell Lid — 1 Piece—USD 100
Quartz-Cell Lid — 1 Piece—USD 66
Solid Sample Tray — 1 Piece—USD 66
Solid Sample Measurement Tray + Lid — 1 Set—USD 118
Solid Reference Component — 1 Piece
Not Barium Sulfate
—USD 66
Liquid Sample Tray — 1 Piece—USD 113
Product configurations follow the supplied specifications. Each Quick Selection option corresponds directly to one of the six price rows.
PURCHASE CHANNELS

Where to Buy

Confirm the instrument model, solid or liquid application, cell design, matching tray and lid arrangement, and reference component requirements before ordering.

Confirm ApplicationSolid / Liquid
Select AccessoryTray / Lid / Reference
Check CompatibilityInstrument and original component design
Place OrderSpecify model and intended use

Partial references citing our materials (from Google Scholar)


Carbon Dioxide Reduction

1. ACS Nano Strain Relaxation in Metal Alloy Catalysts Steers the Product Selectivity of Electrocatalytic CO2 Reduction

The bipolar membrane (Fumasep FBM) in this paper was purchased from SCI Materials Hub, which was used in rechargeable Zn-CO2 battery tests. The authors reported a strain relaxation strategy to determine lattice strains in bimetal MNi alloys (M = Pd, Ag, and Au) and realized an outstanding CO2-to-CO Faradaic efficiency of 96.6% with outstanding activity and durability toward a Zn-CO2 battery.


2. Front. Chem. Boosting Electrochemical Carbon Dioxide Reduction on Atomically Dispersed Nickel Catalyst

In this paper, Vulcan XC-72R was purchased from SCI Materials Hub. Vulcan XC 72R carbon is the most common catalyst support used in the anode and cathode electrodes of Polymer Electrolyte Membrane Fuel Cells (PEMFC), Direct Methanol Fuel Cells (DMFC), Alkaline Fuel Cells (AFC), Microbial Fuel Cells (MFC), Phosphoric Acid Fuel Cells (PAFC), and many more!


3. Adv. Mater. Partially Nitrided Ni Nanoclusters Achieve Energy-Efficient Electrocatalytic CO2 Reduction to CO at Ultralow Overpotential

An AEM membrane (Sustainion X37-50 Grade RT, purchased from SCI Materials Hub) was activated in 1 M KOH for 24 h, washed with ultra-purity water prior to use.


4. Adv. Funct. Mater. Nanoconfined Molecular Catalysts in Integrated Gas Diffusion Electrodes for High-Current-Density CO2 Electroreduction

In this paper (Supporting Information), an anion exchanged membrane (Fumasep FAB-PK-130 obtained from SCI Materials Hub (www.scimaterials.cn)) was used to separate the catholyte and anolyte chambers.

SCI Materials Hub: we also recommend our Fumasep FAB-PK-75 for the use in a flow cell.


5. Appl. Catal. B Efficient utilization of nickel single atoms for CO2 electroreduction by constructing 3D interconnected nitrogen-doped carbon tube network

In this paper, the Nafion 117 membrane was obtained from SCI Materials Hub.


6. Vacuum Modulable Cu(0)/Cu(I)/Cu(II) sites of Cu/C catalysts derived from MOF for highly selective CO2 electroreduction to hydrocarbons

In this paper, Proton exchange membrane (Nafion 117), Nafion D520, and Toray 060 carbon paper were purchased from SCI Materials Hub.


7. National Science Review Confinement of ionomer for electrocatalytic CO2 reduction reaction via efficient mass transfer pathways

An anion exchange membrane (PiperION-A15-HCO3) was obtained from SCI Materials Hub.


8. Catalysis Communications Facilitating CO2 electroreduction to C2H4 through facile regulating {100} & {111} grain boundary of Cu2O

Carbon paper (TGPH060), membrane solution (Nafion D520), and ionic membrane (Nafion N117) were obtained from Wuhu Eryi Material Technology Co., Ltd (a company under SCI Materials Hub).


Batteries

1. J. Mater. Chem. A Blocking polysulfides with a Janus Fe3C/N-CNF@RGO electrode via physiochemical confinement and catalytic conversion for high-performance lithium–sulfur batteries

Graphene oxide (GO) in this paper was obtained from SCI Materials Hub. The authors introduced a Janus Fe3C/N-CNF@RGO electrode consisting of 1D Fe3C decorated N-doped carbon nanofibers (Fe3C/N-CNFs) side and 2D reduced graphene oxide (RGO) side as the free-standing carrier of Li2S6 catholyte to improve the overall electrochemical performance of Li-S batteries.


2. Joule A high-voltage and stable zinc-air battery enabled by dual-hydrophobic-induced proton shuttle shielding

This paper used more than 10 kinds of materials from SCI Materials Hub and the authors gave detailed properity comparsion.

The commercial IEMs of Fumasep FAB-PK-130 and Nafion N117 were obtained from SCI Materials Hub.

Gas diffusion layers of GDL340 (CeTech) and SGL39BC (Sigracet) and Nafion dispersion (Nafion D520) were obtained from SCI Materials Hub.

Zn foil (100 mm thickness) and Zn powder were obtained from the SCI Materials Hub.

Commercial 20% Pt/C, 40% Pt/C and IrO2 catalysts were also obtained from SCI Materials Hub.


3. Journal of Energy Chemistry Vanadium oxide nanospheres encapsulated in N-doped carbon nanofibers with morphology and defect dual-engineering toward advanced aqueous zinc-ion batteries

In this paper, carbon cloth (W0S1011) was obtained from SCI Materials Hub. The flexible carbon cloth matrix guaranteed the stabilization of the electrode and improved the conductivity of the cathode.


4. Energy Storage Materials Defect-abundant commercializable 3D carbon papers for fabricating composite Li anode with high loading and long life

The 3D carbon paper (TGPH060 raw paper) were purchased from SCI Materials Hub.


5. Nanomaterials A Stable Rechargeable Aqueous Zn–Air Battery Enabled by Heterogeneous MoS2 Cathode Catalysts

Nafion D520 (5 wt%), and carbon paper (GDL340) were received from SCI-Materials-Hub.


6. SSRN An Axially Directed Cobalt-Phthalocyanine Covalent Organic Polymer as High-Efficient Bifunctional Catalyst for Zn-Air Battery

Carbon cloth (W0S1011) and other electrochemical consumables required for air cathode were provided by SCI Materials Hub.


Oxygen Reduction Reaction

1. J. Chem. Eng. Superior Efficiency Hydrogen Peroxide Production in Acidic Media through Epoxy Group Adjacent to Co-O/C Active Centers on Carbon Black

In this paper, Vulcan XC 72 carbon black, ion membrane (Nafion N115, 127 μL), Nafion solution (D520, 5 wt%), and carbon paper (AvCarb GDS 2230 and Spectracarb 2050A-1050) were purchased from SCI Materials Hub.


2. Journal of Colloid and Interface Science Gaining insight into the impact of electronic property and interface electrostatic field on ORR kinetics in alloy engineering via theoretical prognostication and experimental validation

The 20 wt% Pt3M (M = Cr, Co, Cu, Pd, Sn, and Ir) were purchased from SCI Materials Hub. This work places emphasis on the kinetics of the ORR concerning Pt3M (M = Cr, Co, Cu, Pd, Sn, and Ir) catalysts, and integrates theoretical prognostication and experimental validation to illuminate the fundamental principles of alloy engineering.


Water Electrolysis

1. International Journal of Hydrogen Energy Gold as an efficient hydrogen isotope separation catalyst in proton exchange membrane water electrolysis

The cathodic catalysts of Pt/C (20 wt%, 2–3 nm) and Au/C (20 wt%, 4–5 nm) were purchased from SCI Materials Hub.


2. Small Science Silver Compositing Boosts Water Electrolysis Activity and Durability of RuO2 in a Proton-Exchange-Membrane Water Electrolyzer

Two fiber felts (0.35 mm thickness, SCI Materials Hub) were used as the porous transport layers at both the cathode and the anode.


3. Advanced Functional Materials Hierarchical Crystalline/Amorphous Heterostructure MoNi/NiMoOx for Electrochemical Hydrogen Evolution with Industry-Level Activity and Stability

Anion-exchange membrane (FAA-3-PK-130) was obtained from SCI Materials Hub website.


Fuel Cells

1. Polymer Sub-two-micron ultrathin proton exchange membrane with reinforced mechanical strength

Gas diffusion electrode (60% Pt/C, Carbon paper) was purchased from SCI Materials Hub.


Characterization

1. Chemical Engineering Journal Electrochemical reconstitution of Prussian blue analogue for coupling furfural electro-oxidation with photo-assisted hydrogen evolution reaction

An Au nanoparticle film was deposited on the total reflecting plane of a single reflection ATR crystal (SCI Materials Hub, Wuhu, China) via sputter coater.

Related Products

We Provide A Broad Range of Materials, Instruments & Solutions in Advanced Science and Technologies About Us
Product consultation
Customer service1
Customer service2
After-sales and technical consultation
Customer service1
Customer service2
WeChat Customer Service

Back to top