Quartz BET Sample Tubes for Micromeritics ASAP 2420
Sample tubes, seals, filters, and analysis and degassing station accessories for surface area, pore size and adsorption testing. Select components by connection size and installation position.
Product Description
Organized by Tube Size, Installation Position & Function
This range supports sample loading, pretreatment, degassing, analysis, sealing, filtration and routine maintenance for ASAP 2420 instruments. Products include 1/2-inch and 3/8-inch BET sample tubes, cold trap tubes, packing rods, loading funnels, seals, ferrules, nuts, adapters, needle valves, filters, tube racks and oil mist filters.
First identify the installation position on the instrument, then verify the sample tube outer diameter, sealing structure and mounting position. Match sample tubes, ferrules and seals by size to avoid mismatches that could affect sealing and measurement stability.
Product Features
Supports Loading, Sealing, Analysis & Maintenance
Clearly Defined Sizes
The 1/2-inch and 3/8-inch series are listed separately for selection by sample tube diameter and matching connection.
Comprehensive Accessories
Includes sample tubes, seals, filters and commonly used analysis and degassing station components.
Easy Maintenance
Consumables and fittings are listed individually for routine inspection, cleaning and scheduled replacement.
Quick Selection
Each specification includes its purpose and description to help select the correct connection and installation position.
Product Specification Comparison
| 1/2-inch Series | 1/2-inch BET Sample TubeWithout Frosted Marking Area | ASAP2420 | Sample Loading & Physisorption Testing | Without a frosted marking area; suitable for routine loading, degassing, BET surface area and pore size testing. | |
| 1/2-inch BET Sample TubeWith Frosted Marking Area | Sample Identification & Adsorption Analysis | A frosted writing area allows sample IDs and batches to be recorded for multiple-sample management. | |||
| 1/2-inch Cold Trap/P0 TubeQuartz Glass | Cold Trapping & P0 Measurement | Quartz glass tube for cold trapping or P0 measurement at the corresponding 1/2-inch connection. | |||
| Packing Rod | Assists Loading of 1/2-inch Sample Tubes | For adjusting internal tube space and assisting sample loading in 1/2-inch BET sample tubes. | |||
| Triangular Loading Funnel | Powder Loading for 1/2-inch Sample Tubes | Guides powder or granular samples into the tube to reduce spills and contamination at the opening. | |||
| Sample Tube Filter & Sealing Plug | Filtration & Sealing for 1/2-inch Sample Tubes | Filters and seals sample tube connections to reduce the risk of particles entering gas lines. | |||
| O-ring | Sealing for 1/2-inch Sample Tube Connections | Fits the corresponding connection. Replace promptly if aged, deformed or damaged on the surface. | |||
| Analysis Station Ferrule | Securing 1/2-inch Analysis Station Connections | Works with the nut and seal to secure the sample tube and stabilize the analysis station connection. | |||
| Degassing Station Ferrule | Securing 1/2-inch Degassing Station Connections | Positions and grips the sample tube at the corresponding degassing station connection; match the size carefully. | |||
| Isothermal Jacket | Stable Liquid-Level Conditions for 1/2-inch Sample Tubes | Helps maintain consistent liquid-level conditions around the sample during analysis for measurement stability. | |||
| Analysis Station Pin | Internal Analysis Station Connection | For the corresponding valve port or connection structure in the analysis station. Match the original component orientation. | |||
| 1/2-inch Analysis Station Blanking Plug | Sealing Unused Analysis Ports | Closes unused 1/2-inch analysis station connections to keep ports clean and sealed. | |||
| 1/2-inch BET Sample Tube Rack | Organized Sample Tube Storage | For organizing, temporarily storing and transferring 1/2-inch BET sample tubes while reducing rolling and impact. | |||
| Cleaning Brush | Internal Cleaning of 1/2-inch Sample Tubes | Removes residual particles inside the tube. Dry thoroughly after cleaning before testing. | |||
| 3/8-inch Series | 3/8-inch BET Sample TubeWithout Frosted Marking Area | Small-Diameter Sample Loading & Adsorption Testing | For routine loading, degassing and physisorption analysis with 3/8-inch connections. | ||
| 3/8-inch BET Sample TubeWith Frosted Marking Area | Sample Marking & Adsorption Testing | A frosted writing area helps clearly distinguish sample IDs and experimental batches. | |||
| Triangular Loading Funnel | Powder Loading for 3/8-inch Sample Tubes | Sized for 3/8-inch sample tubes to guide samples into the tube and keep the opening clean. | |||
| One-way Sample Tube Filter Plug | Particle Retention for 3/8-inch Sample Tubes | Provides one-way filtration for the corresponding sample tube to reduce fine particle entry into system gas lines. | |||
| O-ring | Sealing for 3/8-inch Sample Tube Connections | Fits 3/8-inch connections. Check surface cleanliness, elasticity and integrity before installation. | |||
| Analysis Station Ferrule | Securing 3/8-inch Analysis Station Connections | Positions and secures the analysis station sample tube; match the 3/8-inch tube and sealing structure. | |||
| Degassing Station Ferrule | Securing 3/8-inch Degassing Station Connections | Grips and connects sample tubes at the degassing station. Avoid misalignment and overtightening during assembly. | |||
| General / Specialty | Analysis Station Filter Disc / Element0.5 μm | Particle Filtration in Analysis Station Gas Lines | A 0.5 μm filtration specification for retaining fine particles and helping keep gas lines clean. | ||
| Filter Disc / Element O-ring | Sealing at the Filter Element Mount | Used with the analysis station filter disc or element to seal the filter assembly connection. | |||
| Red Conical Dust Plug | Dust Protection for 1/2-inch & 3/8-inch Sample Tubes | Provides temporary dust protection during tube storage or transfer to reduce entry of foreign matter. | |||
| Vacuum Pump Drying Trap O-ring | Vacuum Pump Drying Trap Connection Sealing | Seals drying trap connections. Replace if hardened, cracked or deformed by compression. | |||
| Analysis Station Nut | Securing 1/2-inch & 3/8-inch Analysis Station Connections | Locks the analysis station sample tube connection; use with the matching ferrule and seal. | |||
| Degassing Station Nut | Securing 1/2-inch & 3/8-inch Degassing Station Connections | Secures degassing station connections. Align correctly and tighten appropriately for the assembly. | |||
| Analysis Station Adapter | Analysis Station Connection Adaptation | Connects corresponding analysis station lines or components. Verify the thread and installation orientation. | |||
| Degassing Station Needle Valve | Degassing Station Gas Flow Control | Opens, closes or adjusts the corresponding degassing station gas line. Avoid overtightening during operation. | |||
| Degassing Station Adapter | 1/2-inch & 3/8-inch Degassing Connections | Adapts relevant degassing station connections. Check the original component structure and dimensions before installation. | |||
| Analysis Station P0 Metal Tubing1 Set | Analysis Station P0 Line Connection | A set of metal tubing for the corresponding P0 measurement line. Check connections and seals after installation. | |||
| Degassing Station Peristaltic Pump TubingShort Version | Short-Run Fluid Transfer at the Degassing Station | Short pump tubing for the corresponding peristaltic pump position. Replace promptly if aged, hardened or worn. | |||
| Degassing Station Peristaltic Pump TubingLong Version | Long-Run Fluid Transfer at the Degassing Station | Long pump tubing for the corresponding installation route. Avoid twisting, kinking and excessive stretching during assembly. | |||
| Degassing Station Oil Mist Filter | Oil Mist Filtration at the Vacuum Pump Exhaust | Filters oil mist at the degassing system vacuum pump exhaust. Inspect and maintain according to use. |
Verify the structure, dimensions and compatibility against the actual connection and original component.
Applications
For Sample Preparation, Testing & Maintenance
Instructions
Follow the Instrument Instructions & Experimental Procedure
Verify Specifications
Check the ASAP 2420 installation position and confirm whether 1/2-inch, 3/8-inch, general or specialty accessories are required.
Inspect & Clean
Check that sample tubes, seals and fittings are clean, dry and free from cracks or visible deformation.
Load & Install
Load the sample with a matching funnel. Install ferrules, seals, nuts or filter components following the original assembly.
Verify Before Testing
After connecting, check the installation and seals, then degas and analyze according to the instrument procedure.
Frequently Asked Questions
Selection & Usage Guidance
What do 1/2 and 3/8 mean?
They identify connection or outer-diameter size series for sample tubes and matching components. 1/2 inch is approximately 12.7 mm and 3/8 inch approximately 9.53 mm; these values do not indicate sample capacity. Check the original sample tube and instrument connection when selecting.
What is the difference between tubes with and without a frosted marking area?
The main difference is the presence of a frosted writing area. This area is useful for recording sample IDs or experimental batches. Both versions must still match the required connection size.
How can I tell when a seal needs replacing?
Inspect and replace the seal with the correct size if it hardens, cracks, fails to recover after compression, has surface scratches or visible deformation, or does not seal properly after connection.
How should sample tubes be handled after use?
Remove residual sample, then clean the inner wall using a suitable method. Dry thoroughly and inspect for cracks, chips or persistent contamination before deciding whether to reuse the tube.