Choose the 1/2-inch, 1/4-inch or 3/8-inch series.
Quartz BET Sample Tubes & Accessories for Micromeritics TriStar 3020
Quartz BET sample tubes, loading tools, seals and analysis station fittings for Micromeritics TriStar 3020 surface area, pore size and adsorption testing. Select components by connection size and intended use.
Product Description
Organized by Tube Size, Installation Position & Function
This range supports sample loading, pretreatment, degassing, analysis, sealing, temperature control assistance and routine maintenance for Micromeritics TriStar 3020 instruments. Products include 1/2-inch, 1/4-inch and 3/8-inch quartz BET sample tubes, packing rods, triangular and straight-neck loading funnels, O-rings, analysis station ferrules and nuts, isothermal jackets and cleaning brushes.
First identify the installation position on the instrument, then verify the sample tube outer diameter, sealing structure and mounting position. Match sample tubes, ferrules and seals by size to avoid mismatches that could affect sealing and measurement stability.
Product Features
Supports Loading, Sealing, Connections & Maintenance
Clearly Defined Sizes
The 1/2-inch, 1/4-inch and 3/8-inch series are listed separately for selection by sample tube diameter and matching connection.
Comprehensive Accessories
Includes sample tubes, loading tools, seals, analysis station fittings, isothermal jackets and cleaning and maintenance accessories.
Easy Maintenance
Seals, fasteners and cleaning accessories are listed separately for routine inspection, cleaning and scheduled replacement.
Quick Selection
Each specification includes its purpose and description to help select the correct connection and installation position.
Product Specification Comparison
| Product Image | Series | Product / Specification | Compatible Model | Main Applications | Product Description |
|---|---|---|---|---|---|
| Sample Tubes / Loading Tools | 1/2-inch BET Sample TubeWithout Frosted Marking Area | TriStar 3020 | Sample Loading & Physisorption Testing | Without a frosted marking area; suitable for routine loading, degassing, BET surface area and pore size testing. | |
| 1/2-inch BET Sample TubeWith Frosted Marking Area | Sample Identification & Adsorption Analysis | A frosted writing area allows sample IDs and batches to be recorded for multiple-sample management. | |||
| 1/4-inch BET Sample TubeWithout Frosted Marking Area | Small-Diameter Sample Loading & Adsorption Testing | For routine loading, degassing and physisorption analysis with 1/4-inch connections. | |||
| 1/4-inch BET Sample TubeWith Frosted Marking Area | Small-Diameter Sample Identification & Testing | A frosted writing area helps distinguish sample IDs or experimental batches for the 1/4-inch series. | |||
| 3/8-inch BET Sample TubeWithout Frosted Marking Area | Sample Loading & Adsorption Testing | For routine loading, degassing and physisorption analysis with 3/8-inch connections. | |||
| 3/8-inch BET Sample TubeWith Frosted Marking Area | Sample Marking & Adsorption Testing | A frosted writing area helps clearly distinguish sample IDs and experimental batches. | |||
| Packing RodFor 1/2-inch BET Sample Tubes | Assists Loading of 1/2-inch Sample Tubes | Adjusts internal tube space and assists loading. Use with matching 1/2-inch sample tubes. | |||
| Packing RodFor 1/4-inch BET Sample Tubes | Assists Loading of 1/4-inch Sample Tubes | Adjusts internal space and assists loading in 1/4-inch sample tubes. Avoid mismatching with other diameters. | |||
| Packing RodFor 3/8-inch BET Sample Tubes | Assists Loading of 3/8-inch Sample Tubes | Adjusts internal space and assists loading in 3/8-inch sample tubes. | |||
| Triangular Loading FunnelFor 1/2-inch BET Sample Tubes | Powder Loading for 1/2-inch Sample Tubes | Guides powder or granular samples into the tube to reduce spills and contamination at the opening. | |||
| Triangular Loading FunnelFor 3/8-inch BET Sample Tubes | Powder Loading for 3/8-inch Sample Tubes | Sized for 3/8-inch sample tubes to guide samples accurately into the tube. | |||
| Straight-Neck Loading FunnelFor 1/2-inch BET Sample Tubes | Loading 1/2-inch Sample Tubes | The straight-neck design facilitates sample loading into 1/2-inch BET sample tubes. | |||
| Straight-Neck Loading FunnelFor 3/8-inch BET Sample Tubes | Loading 3/8-inch Sample Tubes | Sized for 3/8-inch sample tubes for loading powder or granular samples. | |||
| Seals | O-ringFor 1/2-inch BET Sample Tubes | Sealing for 1/2-inch Sample Tube Connections | Provides vacuum sealing at the corresponding connection. Replace promptly if hardened, cracked or deformed. | ||
| O-ringFor 1/4-inch BET Sample Tubes | Sealing for 1/4-inch Sample Tube Connections | Matches 1/4-inch sample tube connections to maintain a seal at the connection. | |||
| O-ringFor 3/8-inch BET Sample Tubes | Sealing for 3/8-inch Sample Tube Connections | Matches 3/8-inch sample tube connections to maintain a seal at the connection. | |||
| Ferrules / Fasteners | Analysis Station FerruleFor 1/2-inch BET Sample Tubes | Securing 1/2-inch Sample Tubes at the Analysis Station | Fits the corresponding analysis station connection to locate and secure the sample tube. | ||
| Analysis Station FerruleFor 3/8-inch BET Sample Tubes | Securing 3/8-inch Sample Tubes at the Analysis Station | Matches 3/8-inch sample tube connections to locate and secure the tube at the analysis station. | |||
| Analysis Station NutFor 1/2-inch BET Sample Tubes | Securing 1/2-inch Sample Tube Connections | Secures 1/2-inch analysis station connections. Use with the matching ferrule and O-ring. | |||
| Analysis Station NutFor 1/4-inch BET Sample Tubes | Securing 1/4-inch Sample Tube Connections | Secures 1/4-inch analysis station connections. Avoid mismatched sizes and overtightening during installation. | |||
| Analysis Station NutFor 3/8-inch BET Sample Tubes | Securing 3/8-inch Sample Tube Connections | Secures 3/8-inch analysis station connections. Use with the matching ferrule and O-ring. | |||
| Temperature Control / Cleaning & Maintenance | Isothermal JacketFor 1/2-inch BET Sample Tubes | Temperature Stability Support for 1/2-inch Sample Tubes | Fits around the corresponding sample tube to help maintain a stable temperature environment during analysis. | ||
| Isothermal JacketFor 3/8-inch BET Sample Tubes | Temperature Stability Support for 3/8-inch Sample Tubes | For 3/8-inch sample tubes. Verify the jacket inner diameter and length before installation. | |||
| Cleaning BrushFor 1/2-inch BET Sample Tubes | Internal Cleaning of 1/2-inch Sample Tubes | Removes residue from the inner wall of the sample tube. Avoid excessive force that could damage the glass. | |||
| Cleaning BrushFor 3/8-inch BET Sample Tubes | Internal Cleaning of 3/8-inch Sample Tubes | The brush head is sized for 3/8-inch sample tubes. Rinse thoroughly and dry after cleaning. |
Verify the structure, dimensions and compatibility against the actual connection and original component.
Applications
For Sample Preparation, Testing & Maintenance
Instructions
Follow the Instrument Instructions & Experimental Procedure
Verify Specifications
Check the TriStar 3020 installation position and confirm whether 1/2-inch, 1/4-inch, 3/8-inch or corresponding specialty accessories are required.
Inspect & Clean
Check that sample tubes, seals and fittings are clean, dry and free from cracks or visible deformation.
Load & Install
Load the sample with a matching funnel. Install ferrules, seals, nuts or filter components following the original assembly.
Verify Before Testing
After connecting, check the installation and seals, then degas and analyze according to the instrument procedure.
Frequently Asked Questions
Selection & Usage Guidance
What do 1/2 and 3/8 mean?
They identify connection or outer-diameter size series for sample tubes and matching components. 1/2 inch is approximately 12.7 mm and 3/8 inch approximately 9.53 mm; these values do not indicate sample capacity. Check the original sample tube and instrument connection when selecting.
What is the difference between tubes with and without a frosted marking area?
The main difference is the presence of a frosted writing area. This area is useful for recording sample IDs or experimental batches. Both versions must still match the required connection size.
How can I tell when a seal needs replacing?
Inspect and replace the seal with the correct size if it hardens, cracks, fails to recover after compression, has surface scratches or visible deformation, or does not seal properly after connection.
How should sample tubes be handled after use?
Remove residual sample, then clean the inner wall using a suitable method. Dry thoroughly and inspect for cracks, chips or persistent contamination before deciding whether to reuse the tube.