Confirm the product variant you wish to purchase.
Quartz BET Sample Tubes & Accessories for Micromeritics Gemini VII 2390
Quartz BET sample tubes and loading, sealing and cleaning accessories for Gemini VII 2390 surface area, pore size and physisorption testing. Select by tube type, length and intended use.
Product Description
Organized by Tube Size, Installation Position & Function
This range supports sample loading, degassing, adsorption analysis, connection sealing and routine cleaning and maintenance for Gemini VII 2390 instruments. Products include 155 mm and 205 mm straight tubes, bulb tubes, and matching packing rods, loading funnels, seals and sample tube brushes.
First confirm the required tube type and length, then check the instrument connection, installation space and sample loading requirements. Match tubes and accessories by structure to avoid size or application mismatches that could affect sealing and measurement stability.
Product Features
Supports Loading, Sealing, Connections & Maintenance
Clearly Defined Sizes
The 155 mm straight tubes, 205 mm straight tubes and bulb tubes are listed separately for selection by tube type, length and loading requirements.
Comprehensive Accessories
Includes straight tubes, bulb tubes, packing rods, loading funnels, seals and sample tube brushes.
Easy Maintenance
Packing rods, funnels, seals and sample tube brushes are listed separately for loading, sealing, cleaning and scheduled replacement.
Quick Selection
Each tube type and accessory includes its purpose and description to help select the correct length, tube type and application.
Product Specification Comparison
| Product Image | Series | Product / Specification | Compatible Model | Main Applications | Product Description |
|---|---|---|---|---|---|
| Quartz BET Sample Tubes | 155 mm Straight Tube1 Piece | Gemini VII 2390 | Routine Sample Loading & Adsorption Testing | A 155 mm straight tube for routine loading, degassing, BET surface area and pore size analysis with the corresponding connection. | |
| 205 mm Straight Tube1 Piece | Long-Tube Sample Loading & Adsorption Testing | A 205 mm straight tube. Confirm instrument installation space, connection dimensions and sample requirements before use. | |||
| Bulb Tube1 Piece | Powder Sample Loading & Adsorption Analysis | The enlarged chamber accommodates samples for physisorption testing that requires greater loading space. | |||
| Sample Loading Accessories | Packing Rod for Bulb Tubes1 Piece | Packing Support for Bulb Tubes | 1 piece. Used with bulb tubes to help adjust internal space and sample position. Avoid mismatching with other tube types. | ||
| Loading Funnel for Bulb Tubes1 Piece | Powder Loading for Bulb Tubes | 1 piece. Guides powder or granular samples into bulb tubes to reduce spills and contamination at the opening. | |||
| Loading Funnel for Straight Tubes1 Piece | Powder Loading for Straight Tubes | 1 piece. The slender funnel stem facilitates sample loading into straight tubes. Confirm that the tube opening matches the funnel outer diameter before use. | |||
| Sealing / Cleaning Accessories | Compatible Sealing Ring1 Piece | Sample Tube Connection Sealing | 1 piece. Provides an airtight seal at the corresponding connection. Replace promptly if hardened, cracked, deformed or contaminated. | ||
| Sample Tube Brush1 Piece | Sample Tube Inner Wall Cleaning | 1 piece. Removes residue from the sample tube inner wall. Avoid excessive bending or force that could damage the quartz tube. |
Verify the structure, dimensions and compatibility against the actual connection and original component.
Applications
For Sample Preparation, Testing & Maintenance
Instructions
Follow the Instrument Instructions & Experimental Procedure
Verify Specifications
Check the Gemini VII 2390 installation position and confirm whether a 155 mm straight tube, 205 mm straight tube, bulb tube or corresponding specialty accessory is required.
Inspect & Clean
Check that sample tubes, packing rods, funnels and seals are clean, dry and free from cracks or visible deformation.
Load & Install
Load samples using a matching funnel. When a bulb tube requires a packing rod, fit it according to the original assembly and install the corresponding seal.
Verify Before Testing
After installation, check the sample tube position and seal, then test according to the Gemini VII 2390 instrument procedure.
Frequently Asked Questions
Selection & Usage Guidance
How do I choose between 155 mm straight tubes, 205 mm straight tubes and bulb tubes?
155 mm and 205 mm indicate nominal straight tube lengths. Choose according to instrument installation space, original tube length and experimental requirements. Bulb tubes have a larger sample chamber for applications requiring greater loading space. Check the original tube type, overall length and connection structure before ordering.
What are the functions of packing rods and loading funnels?
Packing rods are used with bulb tubes to help adjust internal space and sample position. Loading funnels guide powder or granular samples into sample tubes to reduce spills and contamination at the opening. Match both accessories to the corresponding tube type.
How can I tell when a seal needs replacing?
Inspect and replace the seal with the correct size if it hardens, cracks, fails to recover after compression, has surface scratches or visible deformation, or does not seal properly after connection.
How should sample tubes be handled after use?
Remove residual sample, then clean the inner wall using a suitable method. Dry thoroughly and inspect for cracks, chips or persistent contamination before deciding whether to reuse the tube.