Welcome to the SCI Materials Hub !
Home > BET > BET Sample Tube > Quartz Adsorption Sample Tube for Micromeritics 3Flex

Quartz Adsorption Sample Tube for Micromeritics 3Flex

  • Product Code:
  • Description:Quartz Adsorption Sample Tube for Micromeritics 3Flex
  • Brand:
  • Lead time:Ask for quote
  • Views:
  • Telephone:+86 153-5789-9751; +86 156-0553-2352
  • Keywords:Quartz Adsorption Sample Tube for Micromeritics 3Flex
3FLEX SERIES ACCESSORIES

Quartz BET Sample Tubes & Accessories for 3Flex

Includes quartz BET sample tubes, chemisorption tubes, loading accessories, seals and protective components, analysis/degassing station accessories, cleaning and storage products, peristaltic pump tubing and oil mist filters. Select by installation position and intended use.

Quartz Sample TubesLoading & SealingAnalysis & Degassing Station Accessories

Product Description

This range supports sample loading, degassing, physisorption/chemisorption analysis, connection sealing and routine maintenance for 3Flex instruments. Flat-bottom tubes, spherical-bulb tubes, chemisorption tubes and accessories differ in structure and installation position. Select according to the original component shape, instrument connection and experimental requirements.

Product images illustrate component structures. Check the listed product variant against the original component when selecting.

Check Before Ordering
Verify the tube type and frosted marking area, packing rod length, seal location, pump tubing length, and corresponding analysis or degassing station installation position.

Specifications & Accessory Details

Product ImageCategoryProduct VariantCompatible SeriesMain UseProduct Description
For 3Flex Quartz Flat-Bottom Sample Tube (Without Frosted Marking Area)Quartz BET Sample TubesQuartz Flat-Bottom Sample Tube (Without Frosted Marking Area)3Flex SeriesRoutine Physisorption TestingFlat-bottom design without a frosted writing area, for routine loading, degassing and analysis at the corresponding 3Flex connection.
For 3Flex Quartz Flat-Bottom Sample Tube (With Frosted Marking Area)Quartz Flat-Bottom Sample Tube (With Frosted Marking Area)Physisorption Testing Requiring Sample IdentificationFlat-bottom design with a frosted writing area for recording sample IDs or experimental batches.
For 3Flex Quartz Spherical-Bulb Sample Tube (Without Frosted Marking Area)Quartz Spherical-Bulb Sample Tube (Without Frosted Marking Area)Sample Testing in Spherical-Bulb TubesSpherical sample chamber without a frosted writing area. Verify the original tube type and instrument connection before use.
For 3Flex Quartz Spherical-Bulb Sample Tube (With Frosted Marking Area)Quartz Spherical-Bulb Sample Tube (With Frosted Marking Area)Spherical-Bulb Tube Testing Requiring Sample IdentificationSpherical sample chamber with a frosted writing area for sample and batch identification.
For 3Flex Quartz Chemisorption TubeQuartz Chemisorption TubeChemisorption ExperimentsMulti-branch quartz tube for the corresponding 3Flex chemisorption testing position. Verify connection orientation before installation.
For 3Flex Quartz Sample Tube Stopper (With Packing Rod Suspension)Sample Loading AccessoriesQuartz Sample Tube Stopper (With Packing Rod Suspension)Sample Tube Closure & Packing Rod SuspensionIncludes a seal and suspension structure for the matching sample tube opening and packing rod. Packing rod is not included.
For 3Flex Quartz Sample Tube Packing Rod (Standard)Quartz Sample Tube Packing Rod (Standard)Internal Space Adjustment — Standard LengthStandard-length quartz packing rod for use with the matching stopper and sample tube.
For 3Flex Quartz Sample Tube Packing Rod (Extended)Quartz Sample Tube Packing Rod (Extended)Internal Space Adjustment — Extended LengthExtended quartz packing rod. Verify the original rod length and connection structure before ordering.
For 3Flex Quartz Sample Tube Loading FunnelQuartz Sample Tube Loading FunnelPowder or Granular Sample LoadingA long-stem quartz funnel guides samples into the tube to reduce spills and contamination at the opening.
For 3Flex Red Conical Dust PlugSealing & ProtectionRed Conical Dust PlugSample Tube Dust ProtectionRed conical plug for temporary dust protection of sample tubes or related connections. Check the opening diameter before use.
For 3Flex Quartz Sample Tube O-ringQuartz Sample Tube O-ringSample Tube Connection SealingSmall O-ring for the corresponding quartz sample tube connection. Replace if hardened, cracked or deformed.
For 3Flex Vacuum Pump Drying Trap O-ringVacuum Pump Drying Trap O-ringVacuum Pump Drying Trap SealingLarge O-ring for the corresponding vacuum pump drying trap position. Do not interchange with sample tube O-rings.
For 3Flex Thermal Insulation JacketAnalysis & Degassing Station AccessoriesThermal Insulation JacketSample Tube Thermal Insulation SupportWhite cylindrical jacket providing thermal insulation support for the corresponding sample tube. Check length and inner diameter before installation.
For 3Flex Analysis Station Quartz Blanking PlugAnalysis Station Quartz Blanking PlugAnalysis Station Connection BlankingClear quartz plug for closing and protecting the corresponding analysis station connection.
For 3Flex Degassing Station Needle ValveDegassing Station Needle ValveDegassing Station Gas Flow AdjustmentNeedle valve with two connections and a metal adjustment end for the corresponding degassing station gas line position.
For 3Flex Sample Tube RackStorage & CleaningSample Tube RackSample Tube Storage & TransferMulti-hole metal rack for upright sample tube storage. Sample tubes shown in the image illustrate use only.
For 3Flex Quartz Sample Tube Cleaning BrushQuartz Sample Tube Cleaning BrushSample Tube Inner Wall CleaningLong-handled white brush for cleaning sample tube inner walls. Avoid excessive bending or scratching the quartz tube.
For 3Flex Degassing Station Peristaltic Pump Tubing (Short Version)Pump Tubing & FiltrationDegassing Station Peristaltic Pump Tubing (Short Version)Short-Run Pump Tubing ConnectionShort flexible peristaltic pump tubing for the corresponding degassing station position. Verify length and connections before ordering.
For 3Flex Degassing Station Peristaltic Pump Tubing (Long Version)Degassing Station Peristaltic Pump Tubing (Long Version)Long-Run Pump Tubing ConnectionLong flexible peristaltic pump tubing for the corresponding degassing station position. Do not select specifications by color alone.
For 3Flex Degassing Station Oil Mist FilterDegassing Station Oil Mist FilterDegassing Station Oil Mist FiltrationFilter with a blue protective housing for the corresponding 3Flex degassing station oil mist filtration position.

Selection Guide

First Select the Tube Structure

Distinguish flat-bottom, spherical-bulb and chemisorption tubes. For flat-bottom and spherical-bulb tubes, also confirm whether a frosted writing area is required.

Then Select Loading Accessories & Seals

Standard/extended packing rods, stoppers with packing rod suspension, loading funnels and O-rings for two different locations are not interchangeable.

Finally Check the Installation Position

Select thermal insulation jackets, quartz plugs, needle valves, pump tubing and oil mist filters for the corresponding analysis station, degassing station or vacuum pump position.

Typical Applications

Physisorption Analysis

Use matching flat-bottom or spherical-bulb quartz BET sample tubes for loading, degassing, surface area and pore size testing.

Chemisorption Experiments

Chemisorption tubes have a multi-branch structure. Match the connection orientation and port positions to the original tube and instrument.

Maintenance & Consumable Replacement

Regularly inspect seals, pump tubing, filters and needle valves, and clean quartz sample tubes with a dedicated brush.

Operating Steps

Confirm the Model

Verify the 3Flex series, original component structure, dimensions and installation position.

Inspect Condition

Check that quartz components are free from cracks, seals are not hardened and pump tubing shows no obvious aging.

Load & Install

Use a funnel, packing rod and matching stopper as required, and install seals correctly.

Testing & Maintenance

Confirm connections and airtightness before operating according to the instrument procedure. Clean and store promptly after use.

Frequently Asked Questions

What is the difference between tubes with and without a frosted marking area?

The frosted marking area is a writable surface for sample IDs or experimental batches; it does not indicate tube capacity. Also verify whether a flat-bottom or spherical-bulb structure is required.

How do I choose between standard and extended packing rods?

Select according to the original rod length, internal sample tube space and stopper suspension structure. Do not rely on image proportions alone.

Are the two types of O-rings interchangeable?

Do not assume interchangeability. Sample tube and vacuum pump drying trap O-rings differ in size and location. Check against the original component and installation position.

Are the sample tubes shown in the rack image included with the rack?

No. The sample tubes only illustrate how the rack is used.

3FLEX SAMPLE TUBES & ACCESSORIES

Quartz BET Sample Tubes for Micromeritics 3Flex

Compare specifications and prices.

Sample Tubes Sample Tube Accessories Station Accessories Other Accessories 20-Product Price Comparison
Specifications & Prices

Specifications & Price Comparison

SeriesProduct / SpecificationCompatible ModelPack SizePrice (USD)
ASample Tubes
For 3Flex Quartz Flat-Bottom Sample Tube (Without Frosted Marking Area)3Flex1 Piece$36
For 3Flex Quartz Flat-Bottom Sample Tube (With Frosted Marking Area)1 Piece$38
For 3Flex Quartz Spherical-Bulb Sample Tube (Without Frosted Marking Area)1 Piece$36
For 3Flex Quartz Spherical-Bulb Sample Tube (With Frosted Marking Area)1 Piece$38
For 3Flex Quartz Chemisorption Tube1 Piece$68
BSample Tube Accessories
For 3Flex Quartz Sample Tube Stopper (With Packing Rod Suspension)1 Piece$204
For 3Flex Quartz Sample Tube Packing Rod (Standard)1 Piece$26
For 3Flex Quartz Sample Tube Packing Rod (Extended)1 Piece$34
For 3Flex Quartz Sample Tube Loading Funnel1 Piece$26
For 3Flex Red Conical Dust Plug1 Piece$10
For 3Flex Quartz Sample Tube O-ring1 Piece$6
CStation Accessories
For 3Flex Vacuum Pump Drying Trap O-ring1 Piece$30
For 3Flex Thermal Insulation Jacket1 Piece$672
For 3Flex Analysis Station Quartz Blanking Plug1 Piece$12
For 3Flex Degassing Station Needle Valve1 Piece$114
DOther Accessories
Sample Tube Rack$106
For 3Flex Quartz Sample Tube Cleaning Brush1 Piece$8
For 3Flex Degassing Station Peristaltic Pump Tubing (Short Version)1 Piece$34
For 3Flex Degassing Station Peristaltic Pump Tubing (Long Version)1 Piece$68
For 3Flex Degassing Station Oil Mist Filter1 Piece$480
All prices are in USD. Confirm specifications, pack sizes and current availability before ordering.
Selection Process

Ordering Process

01 Confirm the Product

Confirm the product variant you wish to purchase.

02 Confirm the Model

Confirm compatibility with 3Flex.

03 Confirm Pack Size

Confirm the single-piece pack size.

04 Choose a Store

Select a store below once links are available. Multiple items can be combined in a bulk inquiry.

Purchase Channels

Purchase Channels and Ordering Process

Standard specifications can be purchased directly. Confirm the series, connection size, product specifications and instrument compatibility before placing an order.

01Select Series
02Verify Dimensions
03Confirm Compatibility
04Place Order

Partial references citing our materials (from Google Scholar)


Carbon Dioxide Reduction

1. ACS Nano Strain Relaxation in Metal Alloy Catalysts Steers the Product Selectivity of Electrocatalytic CO2 Reduction

The bipolar membrane (Fumasep FBM) in this paper was purchased from SCI Materials Hub, which was used in rechargeable Zn-CO2 battery tests. The authors reported a strain relaxation strategy to determine lattice strains in bimetal MNi alloys (M = Pd, Ag, and Au) and realized an outstanding CO2-to-CO Faradaic efficiency of 96.6% with outstanding activity and durability toward a Zn-CO2 battery.


2. Front. Chem. Boosting Electrochemical Carbon Dioxide Reduction on Atomically Dispersed Nickel Catalyst

In this paper, Vulcan XC-72R was purchased from SCI Materials Hub. Vulcan XC 72R carbon is the most common catalyst support used in the anode and cathode electrodes of Polymer Electrolyte Membrane Fuel Cells (PEMFC), Direct Methanol Fuel Cells (DMFC), Alkaline Fuel Cells (AFC), Microbial Fuel Cells (MFC), Phosphoric Acid Fuel Cells (PAFC), and many more!


3. Adv. Mater. Partially Nitrided Ni Nanoclusters Achieve Energy-Efficient Electrocatalytic CO2 Reduction to CO at Ultralow Overpotential

An AEM membrane (Sustainion X37-50 Grade RT, purchased from SCI Materials Hub) was activated in 1 M KOH for 24 h, washed with ultra-purity water prior to use.


4. Adv. Funct. Mater. Nanoconfined Molecular Catalysts in Integrated Gas Diffusion Electrodes for High-Current-Density CO2 Electroreduction

In this paper (Supporting Information), an anion exchanged membrane (Fumasep FAB-PK-130 obtained from SCI Materials Hub (www.scimaterials.cn)) was used to separate the catholyte and anolyte chambers.

SCI Materials Hub: we also recommend our Fumasep FAB-PK-75 for the use in a flow cell.


5. Appl. Catal. B Efficient utilization of nickel single atoms for CO2 electroreduction by constructing 3D interconnected nitrogen-doped carbon tube network

In this paper, the Nafion 117 membrane was obtained from SCI Materials Hub.


6. Vacuum Modulable Cu(0)/Cu(I)/Cu(II) sites of Cu/C catalysts derived from MOF for highly selective CO2 electroreduction to hydrocarbons

In this paper, Proton exchange membrane (Nafion 117), Nafion D520, and Toray 060 carbon paper were purchased from SCI Materials Hub.


7. National Science Review Confinement of ionomer for electrocatalytic CO2 reduction reaction via efficient mass transfer pathways

An anion exchange membrane (PiperION-A15-HCO3) was obtained from SCI Materials Hub.


8. Catalysis Communications Facilitating CO2 electroreduction to C2H4 through facile regulating {100} & {111} grain boundary of Cu2O

Carbon paper (TGPH060), membrane solution (Nafion D520), and ionic membrane (Nafion N117) were obtained from Wuhu Eryi Material Technology Co., Ltd (a company under SCI Materials Hub).


Batteries

1. J. Mater. Chem. A Blocking polysulfides with a Janus Fe3C/N-CNF@RGO electrode via physiochemical confinement and catalytic conversion for high-performance lithium–sulfur batteries

Graphene oxide (GO) in this paper was obtained from SCI Materials Hub. The authors introduced a Janus Fe3C/N-CNF@RGO electrode consisting of 1D Fe3C decorated N-doped carbon nanofibers (Fe3C/N-CNFs) side and 2D reduced graphene oxide (RGO) side as the free-standing carrier of Li2S6 catholyte to improve the overall electrochemical performance of Li-S batteries.


2. Joule A high-voltage and stable zinc-air battery enabled by dual-hydrophobic-induced proton shuttle shielding

This paper used more than 10 kinds of materials from SCI Materials Hub and the authors gave detailed properity comparsion.

The commercial IEMs of Fumasep FAB-PK-130 and Nafion N117 were obtained from SCI Materials Hub.

Gas diffusion layers of GDL340 (CeTech) and SGL39BC (Sigracet) and Nafion dispersion (Nafion D520) were obtained from SCI Materials Hub.

Zn foil (100 mm thickness) and Zn powder were obtained from the SCI Materials Hub.

Commercial 20% Pt/C, 40% Pt/C and IrO2 catalysts were also obtained from SCI Materials Hub.


3. Journal of Energy Chemistry Vanadium oxide nanospheres encapsulated in N-doped carbon nanofibers with morphology and defect dual-engineering toward advanced aqueous zinc-ion batteries

In this paper, carbon cloth (W0S1011) was obtained from SCI Materials Hub. The flexible carbon cloth matrix guaranteed the stabilization of the electrode and improved the conductivity of the cathode.


4. Energy Storage Materials Defect-abundant commercializable 3D carbon papers for fabricating composite Li anode with high loading and long life

The 3D carbon paper (TGPH060 raw paper) were purchased from SCI Materials Hub.


5. Nanomaterials A Stable Rechargeable Aqueous Zn–Air Battery Enabled by Heterogeneous MoS2 Cathode Catalysts

Nafion D520 (5 wt%), and carbon paper (GDL340) were received from SCI-Materials-Hub.


6. SSRN An Axially Directed Cobalt-Phthalocyanine Covalent Organic Polymer as High-Efficient Bifunctional Catalyst for Zn-Air Battery

Carbon cloth (W0S1011) and other electrochemical consumables required for air cathode were provided by SCI Materials Hub.


Oxygen Reduction Reaction

1. J. Chem. Eng. Superior Efficiency Hydrogen Peroxide Production in Acidic Media through Epoxy Group Adjacent to Co-O/C Active Centers on Carbon Black

In this paper, Vulcan XC 72 carbon black, ion membrane (Nafion N115, 127 μL), Nafion solution (D520, 5 wt%), and carbon paper (AvCarb GDS 2230 and Spectracarb 2050A-1050) were purchased from SCI Materials Hub.


2. Journal of Colloid and Interface Science Gaining insight into the impact of electronic property and interface electrostatic field on ORR kinetics in alloy engineering via theoretical prognostication and experimental validation

The 20 wt% Pt3M (M = Cr, Co, Cu, Pd, Sn, and Ir) were purchased from SCI Materials Hub. This work places emphasis on the kinetics of the ORR concerning Pt3M (M = Cr, Co, Cu, Pd, Sn, and Ir) catalysts, and integrates theoretical prognostication and experimental validation to illuminate the fundamental principles of alloy engineering.


Water Electrolysis

1. International Journal of Hydrogen Energy Gold as an efficient hydrogen isotope separation catalyst in proton exchange membrane water electrolysis

The cathodic catalysts of Pt/C (20 wt%, 2–3 nm) and Au/C (20 wt%, 4–5 nm) were purchased from SCI Materials Hub.


2. Small Science Silver Compositing Boosts Water Electrolysis Activity and Durability of RuO2 in a Proton-Exchange-Membrane Water Electrolyzer

Two fiber felts (0.35 mm thickness, SCI Materials Hub) were used as the porous transport layers at both the cathode and the anode.


3. Advanced Functional Materials Hierarchical Crystalline/Amorphous Heterostructure MoNi/NiMoOx for Electrochemical Hydrogen Evolution with Industry-Level Activity and Stability

Anion-exchange membrane (FAA-3-PK-130) was obtained from SCI Materials Hub website.


Fuel Cells

1. Polymer Sub-two-micron ultrathin proton exchange membrane with reinforced mechanical strength

Gas diffusion electrode (60% Pt/C, Carbon paper) was purchased from SCI Materials Hub.


Characterization

1. Chemical Engineering Journal Electrochemical reconstitution of Prussian blue analogue for coupling furfural electro-oxidation with photo-assisted hydrogen evolution reaction

An Au nanoparticle film was deposited on the total reflecting plane of a single reflection ATR crystal (SCI Materials Hub, Wuhu, China) via sputter coater.

Related Products

We Provide A Broad Range of Materials, Instruments & Solutions in Advanced Science and Technologies About Us
Product consultation
Customer service1
Customer service2
After-sales and technical consultation
Customer service1
Customer service2
WeChat Customer Service

Back to top