Product Description
This range is suitable for Quantachrome Nova, S1 and EVO gas adsorption analyzers. Products include quartz BET sample tubes, P0 tubes, packing rods, loading funnels and connection accessories. Tube types differ in length, diameter, end chamber, dimple position and intended installation.
Select according to the exact instrument model and original component. Check tube length, outer diameter, end structure, connection positions and matching accessories rather than relying on the name alone.
Verify the instrument model, original tube type, length and outer diameter, end structure, dimple position and connection dimensions.
Product Specification Comparison
| Product Image | Category | Product Variant | Compatible Model | Purpose | Structure Description |
|---|---|---|---|---|---|
| Quartz Sample Tubes | Sample Tube for Nova 600 | Nova 600 | Sample Loading & Adsorption Analysis | Spherical sample chamber with a straight tube. Check the original tube length, diameter and end shape before ordering. | |
| 150 mm Sample Tube for Nova 800 | Nova 800 | Sample Testing with 150 mm Tubes | Straight quartz sample tube with a nominal length of 150 mm. Confirm against the original tube dimensions. | ||
| Sample Tube for Nova 800 (With Dimple) | Sample Testing with Dimpled Tubes | Straight tube with a locating dimple. Match the dimple position to the original tube. | |||
| 9 mm Straight Tube | Nova 9 mm Series | Sample Loading in Straight Tubes | 9 mm straight tube. Check outer diameter, length and end structure before use. | ||
| / | Nova 800 P0 Tubes | Nova 800 | P0 Measurement Lines | A P0 quartz tube combination. Match each tube by original quantity, tube type and installation position. | |
| P0 Tube for EVO | EVO | EVO P0 Measurement | Slender straight tube with a shaped end for the corresponding EVO installation position. | ||
| P0 Tube for S1 | S1 | S1 P0 Measurement | Slender straight tube with a small end chamber for the corresponding S1 installation position. | ||
| Packing Rod | Packing Rod for Nova 600 Sample Tubes | Nova 600 | Reduces Sample Tube Free Volume | Clear quartz packing rod with end structure and length suited to Nova 600 sample tubes. | |
| Packing Rod | General Purpose | Reduces Internal Free Space | Straight quartz packing rod. Select according to the original rod length, diameter and end structure. | ||
| Packing Rod for Nova 800 Dimpled Sample Tubes | Nova 800 | For Use with Dimpled Sample Tubes | For dimpled sample tubes. Check length and end position before installation. | ||
| Packing Rod for Nova 800 Sample Tubes | For Use with Nova 800 Sample Tubes | For Nova 800 sample tubes. Check length, diameter and end structure before use. | |||
| Loading Funnels | Loading Funnel | General Purpose | Assists Powder Loading | Conical funnel with a slender stem for guiding samples into sample tubes. | |
| Loading Funnel for 150 mm Nova 800 Tubes | Nova 800 | Loading 150 mm Sample Tubes | Small cup-shaped funnel with a slender stem for the corresponding 150 mm sample tube. | ||
| Loading Funnel for Nova 800 / 600 Sample Tubes | Nova 600 / 800 | Loading Matching Sample Tubes | Includes two funnel structures. Select according to the sample tube opening and original funnel design. | ||
| Seals & Accessories | Filter Plug | Nova Series | Line Filtration | Short cylindrical filter plug with a seal and filter surface. Confirm orientation and airtightness during installation. | |
| Quartz Wool Plug | Sample Retention & Filtration | White plug with a black seal for the corresponding sample tube position. | |||
| Sealing Ring for 6 mm Tubes | 6 mm Tubes | Connection Sealing | Black O-ring for the corresponding 6 mm tube connection. Replace promptly if aged or deformed. | ||
| Instrument Blanking Plug (Quartz) | Nova Series | Instrument Port Blanking | Short cylindrical quartz plug. Check outer diameter, length and connection position before use. | ||
| Soft-Bristle Brush | Sample Tube Cleaning | Soft, slender brush for cleaning sample tube inner walls. Avoid excessive bending during use. |
Product Features
Multiple Models Supported
Covers Nova 600, Nova 800, S1, EVO and related 9 mm tube types for selection by original instrument configuration.
Comprehensive Tubing Accessories
Includes sample tubes, P0 tubes, packing rods, funnels, filter plugs, seals and cleaning accessories.
Clearly Identifiable Structures
Distinguished by spherical chamber, dimple, tube length, end structure and connection design for comparison with original components.
Applications
BET & Gas Adsorption Analysis
For sample loading, degassing and gas adsorption testing on the corresponding Quantachrome instrument.
P0 Measurement & Line Connections
P0 tubes and related quartz tubing serve corresponding measurement positions and instrument line connections.
Sample Loading & Routine Maintenance
Packing rods, funnels, filters, seals and soft brushes support sample loading, sealing, cleaning and maintenance.
Instructions
Verify the Model
Confirm Nova 600, Nova 800, S1, EVO or the 9 mm tube type.
Inspect the Structure
Compare with the original component to verify length, tube diameter, dimple, end chamber and connection positions.
Load & Install
Load using a matching funnel and packing rod. Install in the original orientation and confirm the seal.
Clean & Store
Clean with suitable tools after experiments. Inspect quartz components and seals, then store properly.
FAQ
Are Nova 600, Nova 800, S1 and EVO tubes interchangeable?
Do not assume interchangeability. Length, diameter, end structure and installation position may differ by model. Verify against the instrument model and original component.
How should I select a packing rod for a dimpled sample tube?
Select a rod matching the dimpled tube structure. Check rod length, diameter and end position to avoid affecting loading and installation.
How do I check funnels, filter plugs and seals?
For funnels, check the sample tube opening. For filter plugs, check installation orientation and outer diameter. For seals, check tube diameter and seal groove dimensions.
How should quartz sample tubes be maintained?
Inspect for cracks, chips and residue before use. Clean according to laboratory procedures and dry completely after use. Avoid impact with hard objects and sudden temperature changes.